BECKHOFF BK3120 Profibus Coupler


Brand: Beckhoff
Model: BK3120
Specification:

  • Type: Programmable Controllers
  • Number of Bus Terminals: 64 (255 with K-bus extension)
  • Bus interface: 2 x RJ45
  • Power supply: 24 V DC (-15 %/+20 %)
  • Input current: 70 mA + (total K-bus current)/4,500 mA max

Condition: Used/refurbished
Warranty: Three Months
BECKHOFF BK3120 Manual
Show Other Products

Call for Repair

BECKHOFF BK3120 

The “Economy plus“ version extends the existing PROFIBUS Bus Coupler series BK3120. The K-bus extension technology allows the connection of up to 255 spatially distributed Bus Terminals to one Bus Coupler. The BK3120 designed to accommodate automation requirements. The PROFIBUS protocols omit FMS operation in order to be able to transfer more user data in DP mode, which for this Bus Coupler type can 128 byte inputs and 128 byte outputs. The BK3120 incorporates the PROFIBUS DP V1 services. These services allow direct access to the Bus Coupler register and the complex Bus Terminals in order, for example, to change the parameterisation or to set/correct limit values for analog Bus Terminals. Baud rates of up to 12 Mbaud are automatically recognised by the Bus Coupler, allowing the transmission speed to be adapted to meet the needs of the particular technical process.

The Beckhoff Bus Terminal system unites the advantages of a bus system with the possibilities of the compact series terminal. Bus Terminals can be driven within all the usual bus systems, thus reducing the controller parts count. The Bus Terminals then behave like conventional connections for that bus system. All the performance features of the particular bus system are supported.

Specification:

  • Type: Programmable Controllers
  • Number of Bus Terminals: 64 (255 with K-bus extension)
  • Bus interface: 2 x RJ45
  • Power supply: 24 V DC (-15 %/+20 %)
  • Input current: 70 mA + (total K-bus current)/4,500 mA max
  • Starting current: approx. 2.5 x continuous current
  • Recommended Fuse: Less than or equal to10 A
  • Current supply K bus: 1750 mA
  • Power Contacts: 24 V DC max/10 A max
  • Electrical Isolation: 500 V (power contact/supply voltage/Ethernet)
  • Distance Between Stations: 100 m (100BASE-TX)
  • Weight: Approx 150 g
  • Operating or storage temperature: -25+60 Degree C/-40+85 Degree C
  • Relative Humidity: 95 %, no condensation
  • Vibration or Shock Resistance: conforms to EN 60068-2-6/EN 60068-2-27
  • EMC Immunity or Emission: conforms to EN 61000-6-2/EN 61000-6-4
  • Protect class or Installation position: IP 20/variable