Model:  EM 277 Siemens |  6ES7 277 0AA22 0XA0
Specification: 6ES7 277 0AA22 0XA0 SIMATIC S7-200 PLC, EM 277 PROFIBUS DP SLAVE MODULE, 9.6KB-12MB, 1 PORT, PROFIBUS DP / MPI
Condition: New Original . Germany
Warranty: Three months.
Download Manual
Show Other Products
Call us at +88 01670070357

Call for Repair

EM 277 Siemens Profibus DP Slave  6ES7 277 0AA22 0XA0 

EM 277 Siemens :

 6ES7 277 0AA22 0XA0 is used to interface between a S7-22X CPU and a Profibus DP network. EM 277 Can be simultaneously operated as MPI and DP slave. MPI protocol enables simultaneous data exchange with MPI masters Allows an S7-200 CPU to be connected to a Profibus DP or MPI network as a slave. Various band rates up to 12 Mbaud. With the exception of the module address, which is set with 2 rotary switches, all other settings are in the DP master In MPI mode. Also it can be used to connect operator panels such as TD200 or TDO70 Maximum number of nodes – 31.


Supply voltage

Load voltage L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V

Input current

from backplane bus 5 V DC, max. 150 mA
from sensor current supply or external current supply
(24 V DC), max.
180 mA; 30 to 180 mA

Output voltage

Rated value (DC)
● 5 V DC Yes
● 24 V DC Yes; 20.4 to 28.8V

Output current

For interface (5 V DC), max. 90 mA
For interface (24 V DC), max. 120 mA
● Current limitation 0.7 to 2.4 A

Power loss

Power loss, typ. 2.5 W

Hardware configuration

connectable nodes TD 200 as of V2.0, OP, TP, PG/PC, S7-300/400, PROFIBUS DP
master

Interfaces

Number of RS 485 interfaces 1
MPI
● Number of connections, max. 6
PROFIBUS DP
● Node addresses 0 to 99, adjustable
● Number of stations per segment, max. 32
● Number of stations in network, max. 126; of which max. 99 EM 277
● automatic detection of transmission rate Yes
● Transmission rate, max. 12 Mbit/s; 9,6 / 19,2 / 45,45 / 93,75 / 187,5 / 500 kbit/s; 1 / 1,5 / 3 /
6 / 12 Mbit/s
● Cable length, max. 1 200 m; 100 to 1200 m, depending on transmission speed

Protocols

Bus protocol/transmission protocol PROFIBUS DP (slave), MPI (slave)

Communication functions

Number of connections
● usable for PG communication
— reserved for PG communication 1
● usable for OP communication
— reserved for OP communication 1

Interrupts/diagnostics/status information

Diagnostics indication LED
● Bus fault BF (red) Yes
● CPU error (red) Yes
● DX mode (red) Yes
● Power supply (red) Yes

Isolation

Isolation tested with between external signal and control logic: 500 V AC (galvanic); 5
V DC interface: Isolation between output and module as well as
24 V DC supply voltage: 500 V AC (max. 1 min.); 24 V DC
interface: Isolation no; same circuit as 24 V DC supply voltage

Connection method

Plug-in I/O terminals No

Dimensions

Width 71.2 mm

See other related products
FAQ.

SKU: 5205 Category:
Call Now Button