Lenze EMF 2133 IB Profibus DP Module


Brand: Lenze
Model: EMF 2133 IB
Specification:

  • ID no: 13057309
  • Prod.-No:01624974
  • Ser.-No:0399
  • Module type: Communication Module
  • Communication medium: RS485
  • For use with: Predecessor Module EMF2131 IB
  • Supply Voltage: +24 V DC ±10 %, I = 120 mA
  • Interface: 9−pin Sub−D socket
  • Max. number of stations: 32 (= 1 bus segment), With repeater 125

Condition: Used/Refurbished
Origin: Germany
Warranty: Three Months.

Call for Repair

Lenze Profibus DP Module EMF 2133 IB

Lenze EMF 2133 IB Profibus DP Module :

  • Lenze EMF 2133 IB Profibus DP Module is a Interface module for the PROFIBUS communication system with the
    PROFIBUS−DP−V0 (DRIVECOM profile) and PROFIBUS−DP−V1 (PROFIdrive) communication profiles
  •  Drive profiles:
    – DRIVECOM profile “drive technology 20” (can be switched off)
    – PROFIdrive (can be switched off, state machine and PROFIdrive parameter data
    channel)
  •  Support of the I&M0 functionality for identifying the standard device
  • Automatic detection of the baud rate (9.6 kbps … 12 Mbps)
  • Optionally up to 12 process data words (depending on the basic device)
  • Acyclic parameter access via DP−V1
  • Access to all Lenze parameters
  • External 24V supply for maintaining the PROFIBUS network if the standard device fails
  • DIP switches for …
    – Setting of the node address
    – Setting of the compatibility to the Lenze PROFIBUS communication module EMF2131IB
  • LED status displays:
    – Voltage supply of the communication module
    – Connection from the communication module to the PROFIBUS network
    – Connection from the communication module to the standard device
    – Operating statuses of the standard device

 

Specifications:

Order designation: EMF2133IB
PNO ID number: 2133hex
Communication profile(DIN 19245 Part 1 and Part3): PROFIBUS−DP−V0,PROFIBUS−DP−V1
Communication medium: RS485
Interface: 9−pin Sub−D socket
Drive profile:
DRIVECOM profile “drive technology 20” (can be switched off),
PROFIdrive profile (can be switched off, state machine and PROFIdrive parameter data channel)
Network topology:
without repeaters- Line,
with repeaters- Line or tree
PROFIBUS nodes: Slave
Baud rate [kbps]: 9.6 … 12000 (automatic detection)
Process data words: 1 … 12 words(16 bits/word)
DP user data length:
1 … 12 process data words +
4 parameter data words
Max. number of stations: 
32 (= 1 bus segment)
With repeater: 125
Max. cable length per bus segment: 1200 m (depending on the baud rate and cable type used)
External DC voltage supply V: +24 V DC ±10 %, I = 120 mA