Call:- 01670-070357 to repair your industrial electronics items.

SIEMENS ET200B Distributed IO Module


Brand:  SIEMENS

Model: ET 200B || 6ES7134 0HF01 0XB0

Specification:

Usable terminal block TB8
Supply voltage
Rated value (DC) 24 V; Value at t < 0.5 s: 35 V
permissible range, lower limit (DC) 18.5 V
permissible range, upper limit (DC) 30.2 V
Input current
Current consumption, typ. 70 mA; Logic

Condition: Used/Refurbished

Origin: Germany
Warranty: Three months.

Download Manual
Show Other Products
Call us at +88 01670070357

Call for Repair

ET200B SIEMENS Distributed IO Module 6ES7134 0HF01 0XB0

SIMATIC DP, TERMINAL BLOCK TB4/DC (ET 200B) FOR DIGITAL ELECTR. SUBMODULES WITH 3-WIRE SPRING TERMINALS,W=235MM

IMATIC DP, ELECTRONIC MODULE DIGITAL, FOR ET 200B, W=235MM, 24DI 24V DC, 8DO 24V DC, 0.5A, 0.2MS INPUT DELAY, STANDARD.

SIEMENS ET200B GENERAL INFORMATION :

General information
Usable terminal block TB8
Supply voltage
Rated value (DC) 24 V; Value at t < 0.5 s: 35 V
permissible range, lower limit (DC) 18.5 V
permissible range, upper limit (DC) 30.2 V
Input current
Current consumption, typ. 70 mA; Logic

SPECIFICATION :

Usable terminal block TB8
Supply voltage
Rated value (DC) 24 V; Value at t < 0.5 s: 35 V
permissible range, lower limit (DC) 18.5 V
permissible range, upper limit (DC) 30.2 V
Input current
Current consumption, typ. 70 mA; Logic
Power loss
Power loss, typ. 1.8 W
Analog inputs
Number of analog inputs 4
permissible input voltage for voltage input (destruction limit), max. 30 V; ±30 V (static) or ±75 V (pulse for max. 1 ms and mark to space ratio 1:20)
permissible input current for current input (destruction limit), max. 24 mA
Cycle time (all channels) max. 5 ms
Input ranges
● Voltage Yes
● Current Yes
Input ranges (rated values), voltages
● -1.25 V to +1.25 V Yes
● Input resistance (-1.25 V to +1.25 V) 100 kΩ
● -10 V to +10 V Yes
● Input resistance (-10 V to +10 V) 100 kΩ
● -2.5 V to +2.5 V Yes
● Input resistance (-2.5 V to +2.5 V) 100 kΩ
● -5 V to +5 V Yes
● Input resistance (-5 V to +5 V) 100 kΩ
Input ranges (rated values), currents
● 0 to 20 mA Yes
● Input resistance (0 to 20 mA) 125 Ω
● -20 mA to +20 mA Yes
● Input resistance (-20 mA to +20 mA) 125 Ω
● 4 mA to 20 mA Yes
● Input resistance (4 mA to 20 mA) 125 Ω
Cable length
● shielded, max. 100 m
Analog value generation for the inputs
Measurement principle successive approximation
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 12 bit; Two’s complement
● Integration time (ms) 0.1 ms / channel
Encoder
Connection of signal encoders
● for voltage measurement Yes
● for voltage measurement as 2-wire transducer Yes
● for current measurement as 2-wire transducer Yes
● for current measurement as 4-wire transducer Yes
Errors/accuracies
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-) 32 %; 0 to 60°C
● Current, relative to input range, (+/-) 41 %; 0 to 60°C
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-) 0.15 %
● Current, relative to input range, (+/-) 0.2 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Common mode interference, min. 70 dB; Upp < 1 V
Interfaces
PROFIBUS DP
● Transmission rate, max. 12 Mbit/s
Protocols
Bus protocol/transmission protocol PROFIBUS DP
Interrupts/diagnostics/status information
Alarms
● Diagnostic alarm Yes; Parameterizable
● Limit value alarm Yes; Parameterizable, channels 0 and 2
Diagnostic messages
● Overrange Yes; Rated range
● Wire-break in signal transmitter cable Yes; Measuring range 4 to 20 mA only
Diagnostics indication LED
● RUN LED Yes
● Bus fault BF (red) Yes
Potential separation
between electronic block and PROFIBUS DP Yes
Potential separation analog inputs
● Potential separation analog inputs No
Permissible potential difference
between the inputs (UCM) max. ±10 V
Between the inputs and MANA (UCM) max. ±1 V
Degree and class of protection
Degree of protection acc. to EN 60529 IP20
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C; 41 °C for other mountings
Air pressure acc. to IEC 60068-2-13
● permissible range, lower limit 795 hPa
● permissible range, upper limit 1 080 hPa
Relative humidity
● Operation, min. 15 %
● Operation, max. 95 %; RH class 2 in accordance with IEC 1131-2
Vibrations
● Operation, tested according to IEC 60068-2-6 Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)
Shock testing
● tested according to IEC 60068-2-27 Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms
Connection method
Design of electrical connection for the inputs and outputs Screw-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection
Dimensions
Width 160 mm; EB and TB
Height 130 mm; EB and TB
Depth 60 mm; EB and TB
Weights
Weight, approx. 550 g; EB and TB
last modified: 01/24/2019