Call:- 01670-070357 to repair your industrial electronics items.

SIEMENS CPU313C 2 DP PLC


Brand: Siemens

Model: SIMATIC S7 3000 || 6ES7 313 6CE00 0AB0

Specification:

  • SIMATIC S7-300 CPU 313C-2 DP
  • Compact CPU with MPI
  • 16 DI/16 DO
  • 3 high-speed counters (30 kHz)
  • integrated DP interface
  • Integr. power supply 24 V DC
  • work memory 128 KB
  • Front connector (1x 40-pole)
  • Micro Memory Card

Condition: Used/Refurbished

Origin:  Germany
Warranty: Three months.

Download Manual
Show Other Products
Call us at +88 01670070357

Call for Repair

CPU 313C 2 DP SIEMENS S7 300

SIEMENS SIMATIC S7 6ES7 313 6CE00 0AB0

SIEMENS CPU313C 2 DP :

SIMATIC S7-300, CPU 313C-2 DP Compact CPU with MPI, 16 DI/16 DO, 3 high-speed counters (30 kHz), integrated DP interface, Integr. power supply 24 V DC, work memory 128 KB, Front connector (1x 40-pole) and Micro Memory Card required.

The CPU 313C-2 DP is the compact CPU for systems with a distributed structure. Integrated digital inputs/outputs support direct interfacing with the process; the PROFIBUS DP master/slave interface supports connection to distributed I/O parts. The CPU 313C-2 DP can therefore be used both as a distributed unit for fast preprocessing and as a higher-level controller with a lower-level fieldbus system.

A CPU 313C-2 DP PLC with model number 6ES73136CG040AB0 has been detected. It is described by Siemens as SIMATIC S7-300″ CPU 313C-2 DP Compact CPU with MPI” 16 DI/16 DO” 3 high-speed counters (30 kHz)” integrated DP interface” Integr. power supply 24 V DC” work memory 128 KB” Front connector (1x 40-pole) and Micro Memory Card required.

Specifications :

Article number

6ES7313-6CG04-0AB0

CPU313C-2 DP, 16DI/16DO, 128 KB

General information

HW functional status

01

Firmware version

V3.3

Engineering with

  • ● Programming package

STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203

Supply voltage

Rated value (DC)

  • ● 24 V DC

Yes

permissible range, lower limit (DC)

19.2 V

permissible range, upper limit (DC)

28.8 V

external protection for power supply lines (recommendation)

Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A

Mains buffering

  • ● Mains/voltage failure stored energy time

5 ms

  • ● Repeat rate, min.

1 s

Load voltage L+

Digital inputs

  • — Rated value (DC)

24 V

  • — Reverse polarity protection

Yes

Digital outputs

  • — Rated value (DC)

24 V

  • — Reverse polarity protection

No

Input current

Current consumption (rated value)

800 mA

Current consumption (in no-load operation), typ.

110 mA

Inrush current, typ.

5 A

I²t

0.7 A²·s

Digital inputs

  • ● from load voltage L+ (without load), max.

80 mA

Digital outputs

  • ● from load voltage L+, max.

50 mA

Power loss

Power loss, typ.

9 W

Memory

Work memory

  • ● integrated

128 kbyte

  • ● expandable

No

  • ● Size of retentive memory for retentive data blocks

64 kbyte

Load memory

  • ● Plug-in (MMC)

Yes

  • ● Plug-in (MMC), max.

8 Mbyte

  • ● Data management on MMC (after last programming), min.

10 y

Backup

  • ● present

Yes; Guaranteed by MMC (maintenance-free)

  • ● without battery

Yes; Program and data

CPU processing times

for bit operations, typ.

0.07 µs

for word operations, typ.

0.15 µs

for fixed point arithmetic, typ.

0.2 µs

for floating point arithmetic, typ.

0.72 µs

CPU-blocks

Number of blocks (total)

1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

DB

  • ● Number, max.

1 024; Number range: 1 to 16000

  • ● Size, max.

64 kbyte

FB

  • ● Number, max.

1 024; Number range: 0 to 7999

  • ● Size, max.

64 kbyte

FC

  • ● Number, max.

1 024; Number range: 0 to 7999

  • ● Size, max.

64 kbyte

OB

  • ● Description

see instruction list

  • ● Size, max.

64 kbyte

  • ● Number of free cycle OBs

1; OB 1

  • ● Number of time alarm OBs

1; OB 10

  • ● Number of delay alarm OBs

2; OB 20, 21

  • ● Number of cyclic interrupt OBs

4; OB 32, 33, 34, 35

  • ● Number of process alarm OBs

1; OB 40

  • ● Number of DPV1 alarm OBs

3; OB 55, 56, 57

  • ● Number of startup OBs

1; OB 100

  • ● Number of asynchronous error OBs

5; OB 80, 82, 85, 86, 87

  • ● Number of synchronous error OBs

2; OB 121, 122

Nesting depth

  • ● per priority class

16

  • ● additional within an error OB

4

Counters, timers and their retentivity

S7 counter

  • ● Number

256

Retentivity

  • — adjustable

Yes

  • — lower limit

0

  • — upper limit

255

  • — preset

Z 0 to Z 7

Counting range

  • — lower limit

0

  • — upper limit

999

IEC counter

  • ● present

Yes

  • ● Type

SFB

  • ● Number

Unlimited (limited only by RAM capacity)

S7 times

  • ● Number

256

Retentivity

  • — adjustable

Yes

  • — lower limit

0

  • — upper limit

255

  • — preset

No retentivity

Time range

  • — lower limit

10 ms

  • — upper limit

9 990 s

IEC timer

  • ● present

Yes

  • ● Type

SFB

  • ● Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

retentive data area in total

All, max. 64 KB

Flag

  • ● Number, max.

256 byte

  • ● Retentivity available

Yes; MB 0 to MB 255

  • ● Retentivity preset

MB 0 to MB 15

  • ● Number of clock memories

8; 1 memory byte

Data blocks

  • ● Retentivity adjustable

Yes; via non-retain property on DB

  • ● Retentivity preset

Yes

Local data

  • ● per priority class, max.

32 kbyte; Max. 2048 bytes per block

Address area

I/O address area

  • ● Inputs

2 048 byte

  • ● Outputs

2 048 byte

of which distributed

  • — Inputs

2 030 byte

  • — Outputs

2 030 byte

Process image

  • ● Inputs

2 048 byte

  • ● Outputs

2 048 byte

  • ● Inputs, adjustable

2 048 byte

  • ● Outputs, adjustable

2 048 byte

  • ● Inputs, default

128 byte

  • ● Outputs, default

128 byte

Default addresses of the integrated channels

  • — Digital inputs

124.0 to 125.7

  • — Digital outputs

124.0 to 125.7

Digital channels

  • ● Inputs

16 256

  • — of which central

1 008

  • ● Outputs

16 256

  • — of which central

1 008

Analog channels

  • ● Inputs

1 015

  • — of which central

248

  • ● Outputs

1 015

  • — of which central

248

Hardware configuration

Number of expansion units, max.

3

Number of DP masters

  • ● integrated

1

  • ● via CP

4

Number of operable FMs and CPs (recommended)

  • ● FM

8

  • ● CP, PtP

8

  • ● CP, LAN

6

Rack

  • ● Racks, max.

4

  • ● Modules per rack, max.

8; In rack 3 max. 7

Time of day

Clock

  • ● Hardware clock (real-time)

Yes

  • ● retentive and synchronizable

Yes

  • ● Backup time

6 wk; At 40 °C ambient temperature

  • ● Deviation per day, max.

10 s; Typ.: 2 s

  • ● Behavior of the clock following POWER-ON

Clock continues running after POWER OFF

  • ● Behavior of the clock following expiry of backup period

Clock continues to run with the time at which the power failure occurred

Operating hours counter

  • ● Number

1

  • ● Number/Number range

0

  • ● Range of values

0 to 2^31 hours (when using SFC 101)

  • ● Granularity

1 h

  • ● retentive

Yes; Must be restarted at each restart

Clock synchronization

  • ● supported

Yes

  • ● to MPI, master

Yes

  • ● to MPI, slave

Yes

  • ● to DP, master

Yes; With DP slave only slave clock

  • ● to DP, slave

Yes

  • ● in AS, master

Yes

  • ● in AS, slave

No

Digital inputs

Number of digital inputs

16

  • ● of which inputs usable for technological functions

12

integrated channels (DI)

16

Input characteristic curve in accordance with IEC 61131, type 1

Yes

horizontal installation

  • — up to 40 °C, max.

16

  • — up to 60 °C, max.

8

vertical installation

  • — up to 40 °C, max.

8

Input voltage

  • ● Rated value (DC)

24 V

  • ● for signal “0”

-3 to +5V

  • ● for signal “1”

+15 to +30V

Input current

  • ● for signal “1”, typ.

8 mA

Input delay (for rated value of input voltage)

for standard inputs

  • — parameterizable

Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.)

  • — Rated value

3 ms

for technological functions

  • — at “0” to “1”, max.

16 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency

Cable length

  • ● shielded, max.

1 000 m; 100 m for technological functions

  • ● unshielded, max.

600 m; For technological functions: No

for technological functions

  • — shielded, max.

100 m; at maximum count frequency

  • — unshielded, max.

not allowed

Digital outputs

Number of digital outputs

16

  • ● of which high-speed outputs

4; Notice: You cannot connect the fast outputs of your CPU in parallel

integrated channels (DO)

16

Short-circuit protection

Yes; Clocked electronically

  • ● Response threshold, typ.

1 A

Limitation of inductive shutdown voltage to

L+ (-48 V)

Controlling a digital input

Yes

Switching capacity of the outputs

  • ● on lamp load, max.

5 W

Load resistance range

  • ● lower limit

48 Ω

  • ● upper limit

4 kΩ

Output voltage

  • ● for signal “1”, min.

L+ (-0.8 V)

Output current

  • ● for signal “1” rated value

500 mA

  • ● for signal “1” permissible range, min.

5 mA

  • ● for signal “1” permissible range, max.

0.6 A

  • ● for signal “1” minimum load current

5 mA

  • ● for signal “0” residual current, max.

0.5 mA

Parallel switching of two outputs

  • ● for uprating

No

  • ● for redundant control of a load

Yes

Switching frequency

  • ● with resistive load, max.

100 Hz

  • ● with inductive load, max.

0.5 Hz

  • ● on lamp load, max.

100 Hz

  • ● of the pulse outputs, with resistive load, max.

2.5 kHz

horizontal installation

  • — up to 40 °C, max.

3 A

  • — up to 60 °C, max.

2 A

vertical installation

  • — up to 40 °C, max.

2 A

Cable length

  • ● shielded, max.

1 000 m

  • ● unshielded, max.

600 m

Analog inputs

Number of analog inputs

0

integrated channels (AI)

0

Analog outputs

Number of analog outputs

0

integrated channels (AO)

0

Connectable encoders

  • ● 2-wire sensor

Yes

  • — permissible quiescent current (2-wire sensor), max.

1.5 mA

Interfaces

Number of industrial Ethernet interfaces

0

Number of PROFINET interfaces

0

Number of RS 485 interfaces

2; MPI and PROFIBUS DP

Number of RS 422 interfaces

0

1. Interface

Interface type

Integrated RS 485 interface

Physics

RS 485

Isolated

No

Power supply to interface (15 to 30 V DC), max.

200 mA

Protocols

  • ● MPI

Yes

  • ● PROFIBUS DP master

No

  • ● PROFIBUS DP slave

No

  • ● Point-to-point connection

No

MPI

  • ● Transmission rate, max.

187.5 kbit/s

Services

  • — PG/OP communication

Yes

  • — Routing

Yes

  • — Global data communication

Yes

  • — S7 basic communication

Yes

  • — S7 communication

Yes; Only server, configured on one side

  • — S7 communication, as client

No; but via CP and loadable FB

  • — S7 communication, as server

Yes

2. Interface

Interface type

Integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200 mA

Protocols

  • ● MPI

No

  • ● PROFINET IO Controller

No

  • ● PROFINET IO Device

No

  • ● PROFINET CBA

No

  • ● PROFIBUS DP master

Yes

  • ● PROFIBUS DP slave

Yes

PROFIBUS DP master

  • ● Transmission rate, max.

12 Mbit/s

  • ● Number of DP slaves, max.

124

Services

  • — PG/OP communication

Yes

  • — Routing

Yes

  • — Global data communication

No

  • — S7 basic communication

Yes; I blocks only

  • — S7 communication

Yes; Yes (only server; connection configured at one end)

  • — S7 communication, as client

No

  • — S7 communication, as server

Yes

  • — Equidistance

Yes

  • — Isochronous mode

No

  • — SYNC/FREEZE

Yes

  • — Activation/deactivation of DP slaves

Yes

  • — Number of DP slaves that can be simultaneously activated/deactivated, max.

8

  • — Direct data exchange (slave-to-slave communication)

Yes; As subscriber

  • — DPV1

Yes

Address area

  • — Inputs, max.

2 kbyte

  • — Outputs, max.

2 kbyte

User data per DP slave

  • — Inputs, max.

244 byte

  • — Outputs, max.

244 byte

PROFIBUS DP slave

  • ● GSD file

The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd)

  • ● Transmission rate, max.

12 Mbit/s

  • ● automatic baud rate search

Yes; only with passive interface

  • ● Address area, max.

32

  • ● User data per address area, max.

32 byte

Services

  • — PG/OP communication

Yes

  • — Routing

Yes; Only with active interface

  • — Global data communication

No

  • — S7 basic communication

No

  • — S7 communication

Yes; Yes (only server; connection configured at one end)

  • — S7 communication, as client

No

  • — S7 communication, as server

Yes

  • — Direct data exchange (slave-to-slave communication)

Yes

  • — DPV1

No

Transfer memory

  • — Inputs

244 byte

  • — Outputs

244 byte

Communication functions

PG/OP communication

Yes

Data record routing

Yes

Global data communication

  • ● supported

Yes

  • ● Number of GD loops, max.

8

  • ● Number of GD packets, max.

8

  • ● Number of GD packets, transmitter, max.

8

  • ● Number of GD packets, receiver, max.

8

  • ● Size of GD packets, max.

22 byte

  • ● Size of GD packet (of which consistent), max.

22 byte

S7 basic communication

  • ● supported

Yes

  • ● User data per job, max.

76 byte

  • ● User data per job (of which consistent), max.

76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

S7 communication

  • ● supported

Yes

  • ● as server

Yes

  • ● as client

Yes; Via CP and loadable FB

  • ● User data per job, max.

180 kbyte; With PUT/GET

  • ● User data per job (of which consistent), max.

240 byte; as server

S5 compatible communication

  • ● supported

Yes; via CP and loadable FC

Number of connections

  • ● overall

8

  • ● usable for PG communication

7

  • — reserved for PG communication

1

  • — adjustable for PG communication, min.

1

  • — adjustable for PG communication, max.

7

  • ● usable for OP communication

7

  • — reserved for OP communication

1

  • — adjustable for OP communication, min.

1

  • — adjustable for OP communication, max.

7

  • ● usable for S7 basic communication

4

  • — reserved for S7 basic communication

0

  • — adjustable for S7 basic communication, min.

0

  • — adjustable for S7 basic communication, max.

4

  • ● usable for routing

4; max.

S7 message functions

Number of login stations for message functions, max.

8; Depending on the configured connections for PG/OP and S7 basic communication

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

300

Test commissioning functions

Status block

Yes; Up to 2 simultaneously

Single step

Yes

Number of breakpoints

4

Status/control

  • ● Status/control variable

Yes

  • ● Variables

Inputs, outputs, memory bits, DB, times, counters

  • ● Number of variables, max.

30

  • — of which status variables, max.

30

  • — of which control variables, max.

14

Forcing

  • ● Forcing

Yes

  • ● Forcing, variables

Inputs, outputs

  • ● Number of variables, max.

10

Diagnostic buffer

  • ● present

Yes

  • ● Number of entries, max.

500

  • — adjustable

No

  • — of which powerfail-proof

100; Only the last 100 entries are retained

  • ● Number of entries readable in RUN, max.

499

  • — adjustable

Yes; From 10 to 499

  • — preset

10

Service data

  • ● can be read out

Yes

Interrupts/diagnostics/status information

Diagnostics indication LED

  • ● Status indicator digital input (green)

Yes

  • ● Status indicator digital output (green)

Yes

Integrated Functions

Number of counters

3; See “Technological Functions” manual

Counting frequency (counter) max.

30 kHz

Frequency measurement

Yes

Number of frequency meters

3; up to 30 kHz (see “Technological Functions” manual)

controlled positioning

No

integrated function blocks (closed-loop control)

Yes; PID controller (see “Technological Functions” manual)

PID controller

Yes

Number of pulse outputs

3; Pulse width modulation up to 2.5 kHz (see “Technological Functions” Manual)

Limit frequency (pulse)

2.5 kHz

Potential separation

Potential separation digital inputs

  • ● Potential separation digital inputs

Yes

  • ● between the channels

No

  • ● between the channels and backplane bus

Yes

Potential separation digital outputs

  • ● Potential separation digital outputs

Yes

  • ● between the channels

Yes

  • ● between the channels, in groups of

8

  • ● between the channels and backplane bus

Yes

Isolation

Isolation tested with

600 V DC

Ambient conditions

Ambient temperature during operation

  • ● min.

0 °C

  • ● max.

60 °C

Configuration

Configuration software

  • ● STEP 7

Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203

  • ● STEP 7 Lite

No

Programming

  • ● Command set

see instruction list

  • ● Nesting levels

8

  • ● System functions (SFC)

see instruction list

  • ● System function blocks (SFB)

see instruction list

Programming language

  • — LAD

Yes

  • — FBD

Yes

  • — STL

Yes

  • — SCL

Yes

  • — CFC

Yes

  • — GRAPH

Yes

  • — HiGraph®

Yes

Know-how protection

  • ● User program protection/password protection

Yes

  • ● Block encryption

Yes; With S7 block Privacy

Dimensions

Width

80 mm

Height

125 mm

Depth

130 mm

Weights

Weight, approx.

500 g

SKU: 5380 Category: