ET200B SIEMENS Distributed IO Module 6ES7134 0HF01 0XB0
SIMATIC DP, TERMINAL BLOCK TB4/DC (ET 200B) FOR DIGITAL ELECTR. SUBMODULES WITH 3-WIRE SPRING TERMINALS,W=235MM
IMATIC DP, ELECTRONIC MODULE DIGITAL, FOR ET 200B, W=235MM, 24DI 24V DC, 8DO 24V DC, 0.5A, 0.2MS INPUT DELAY, STANDARD.
SIEMENS ET200B GENERAL INFORMATION :
General information | ||
Usable terminal block | TB8 | |
Supply voltage | ||
Rated value (DC) | 24 V; Value at t < 0.5 s: 35 V | |
permissible range, lower limit (DC) | 18.5 V | |
permissible range, upper limit (DC) | 30.2 V | |
Input current | ||
Current consumption, typ. | 70 mA; Logic |
SPECIFICATION :
Usable terminal block | TB8 | |
Supply voltage | ||
Rated value (DC) | 24 V; Value at t < 0.5 s: 35 V | |
permissible range, lower limit (DC) | 18.5 V | |
permissible range, upper limit (DC) | 30.2 V | |
Input current | ||
Current consumption, typ. | 70 mA; Logic | |
Power loss | ||
Power loss, typ. | 1.8 W | |
Analog inputs | ||
Number of analog inputs | 4 | |
permissible input voltage for voltage input (destruction limit), max. | 30 V; ±30 V (static) or ±75 V (pulse for max. 1 ms and mark to space ratio 1:20) | |
permissible input current for current input (destruction limit), max. | 24 mA | |
Cycle time (all channels) max. | 5 ms | |
Input ranges | ||
● Voltage | Yes | |
● Current | Yes | |
Input ranges (rated values), voltages | ||
● -1.25 V to +1.25 V | Yes | |
● Input resistance (-1.25 V to +1.25 V) | 100 kΩ | |
● -10 V to +10 V | Yes | |
● Input resistance (-10 V to +10 V) | 100 kΩ | |
● -2.5 V to +2.5 V | Yes | |
● Input resistance (-2.5 V to +2.5 V) | 100 kΩ | |
● -5 V to +5 V | Yes | |
● Input resistance (-5 V to +5 V) | 100 kΩ | |
Input ranges (rated values), currents | ||
● 0 to 20 mA | Yes | |
● Input resistance (0 to 20 mA) | 125 Ω | |
● -20 mA to +20 mA | Yes | |
● Input resistance (-20 mA to +20 mA) | 125 Ω | |
● 4 mA to 20 mA | Yes | |
● Input resistance (4 mA to 20 mA) | 125 Ω | |
Cable length | ||
● shielded, max. | 100 m | |
Analog value generation for the inputs | ||
Measurement principle | successive approximation | |
Integration and conversion time/resolution per channel | ||
● Resolution with overrange (bit including sign), max. | 12 bit; Two’s complement | |
● Integration time (ms) | 0.1 ms / channel | |
Encoder | ||
Connection of signal encoders | ||
● for voltage measurement | Yes | |
● for voltage measurement as 2-wire transducer | Yes | |
● for current measurement as 2-wire transducer | Yes | |
● for current measurement as 4-wire transducer | Yes | |
Errors/accuracies | ||
Operational error limit in overall temperature range | ||
● Voltage, relative to input range, (+/-) | 32 %; 0 to 60°C | |
● Current, relative to input range, (+/-) | 41 %; 0 to 60°C | |
Basic error limit (operational limit at 25 °C) | ||
● Voltage, relative to input range, (+/-) | 0.15 % | |
● Current, relative to input range, (+/-) | 0.2 % | |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | ||
● Common mode interference, min. | 70 dB; Upp < 1 V | |
Interfaces | ||
PROFIBUS DP | ||
● Transmission rate, max. | 12 Mbit/s | |
Protocols | ||
Bus protocol/transmission protocol | PROFIBUS DP | |
Interrupts/diagnostics/status information | ||
Alarms | ||
● Diagnostic alarm | Yes; Parameterizable | |
● Limit value alarm | Yes; Parameterizable, channels 0 and 2 | |
Diagnostic messages | ||
● Overrange | Yes; Rated range | |
● Wire-break in signal transmitter cable | Yes; Measuring range 4 to 20 mA only | |
Diagnostics indication LED | ||
● RUN LED | Yes | |
● Bus fault BF (red) | Yes | |
Potential separation | ||
between electronic block and PROFIBUS DP | Yes | |
Potential separation analog inputs | ||
● Potential separation analog inputs | No | |
Permissible potential difference | ||
between the inputs (UCM) | max. ±10 V | |
Between the inputs and MANA (UCM) | max. ±1 V | |
Degree and class of protection | ||
Degree of protection acc. to EN 60529 | IP20 | |
Ambient conditions | ||
Ambient temperature during operation | ||
● horizontal installation, min. | 0 °C | |
● horizontal installation, max. | 60 °C; 41 °C for other mountings | |
Air pressure acc. to IEC 60068-2-13 | ||
● permissible range, lower limit | 795 hPa | |
● permissible range, upper limit | 1 080 hPa | |
Relative humidity | ||
● Operation, min. | 15 % | |
● Operation, max. | 95 %; RH class 2 in accordance with IEC 1131-2 | |
Vibrations | ||
● Operation, tested according to IEC 60068-2-6 | Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g) | |
Shock testing | ||
● tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms | |
Connection method | ||
Design of electrical connection for the inputs and outputs | Screw-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection | |
Dimensions | ||
Width | 160 mm; EB and TB | |
Height | 130 mm; EB and TB | |
Depth | 60 mm; EB and TB | |
Weights | ||
Weight, approx. | 550 g; EB and TB | |
last modified: | 01/24/2019 |