Siemens touch Panel TP177 6AV6640 0CA11 0AX1 

Brand: Siemens
Model: Simatic TP 177 micro / 6av6 640-0ca11-0ax0
Specification: 5.7” STN touchscreen display / HMI. Low-priced entry-level device for basic requirements. Configuration with the WinCC flexible Micro engineering system. Touch Panel for operator control and monitoring of small machines and plants.

Condition: Used/Refurbished
TP177 Micro Manual
Show Other Products
Call: 01670070357

Call for Repair

TP177 MICRO SIEMENS SIMATIC 6AV6640 0CA11 0AX1 

The TP177 Micro Details:

Siemens HMI TP177 Micro

Design of display STN
Screen diagonal 5.7 in
Color display No
Number of colors 4; Blue levels
Resolution (pixels)
● Horizontal image resolution 320 Pixel
● Vertical image resolution 240 Pixel
Backlighting
● MTBF backlighting (at 25 °C) 50 000 h
Control elements
Control elements Touch screen
Keyboard fonts
● Membrane keyboard
— user-definable label membrane keys No
● Function keys No
● System keys No
— Number of system keys 0
● alphanumeric keyboard Yes
● hexadecimal keyboard Yes
● Multi-key operation No
Touch operation
● Design as touch screen Yes; analog, resistive
Installation type/mounting
Mounting position vertical
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
Type of supply voltage DC
Input current
Current consumption (rated value) 0.24 A
Starting current inrush I²t 0.5 A²·s
Power
Active power input, typ. 6 W
Processor
Processor type ARM
Memory
Type of memory Flash
Memory available for user data 256 kbyte
Time of day
Clock
● Type Software clock, no battery backup
● retentive No
● synchronizable No
Interfaces
Interfaces/bus type 1 x RS485 (max. 187.5 kbit/s)
Number of RS 485 interfaces 1
● Transmission rate, max. 187.5 kbit/s
Number of USB interfaces 0
Protocols
Supports protocol for PROFINET IO No
PROFIsafe No
PROFIBUS Yes
Protocols (Ethernet)
● TCP/IP No
Further protocols
● EtherNet/IP No
● MODBUS No
● other bus systems Yes
Degree and class of protection
IP (at the front) IP65
NEMA (front) NEMA 4x (when installed)
IP (rear) IP20
Standards, approvals, certificates
Certifications CE, GL, ABS, BV, DNV, LRS, FM Class I Div. 2, UL, CSA, cULus, EX-Zone 2 (in Vorbereitung), EX-Zone 22 (in Vorbereitung), C-TICK, NEMA 4x
cULus Yes
EAC (formerly Gost-R) No
Suitable for safety functions No
Marine approval
● Germanischer Lloyd (GL) Yes
● American Bureau of Shipping (ABS) Yes
● Bureau Veritas (BV) Yes
● Det Norske Veritas (DNV) Yes
● Lloyds Register of Shipping (LRS) Yes
● Nippon Kaiji Kyokai (Class NK) Yes
● Polski Rejestr Statkow (PRS) No
Use in hazardous areas
● ATEX Zone 2 Yes
● ATEX Zone 22 Yes
● FM Class I Division 2 Yes
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 50 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 90 %
Operating systems
pre-installed operating system LINUX
Configuration
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management No
Configuration software
● Configuration tool WinCC flexible Micro Version 2004 SP1, HSP or higher (to be ordered separately)
● STEP 7 Basic (TIA Portal) No
● STEP 7 Professional (TIA Portal) No
● WinCC flexible Compact Yes
● WinCC flexible Standard Yes
● WinCC flexible Advanced Yes
● WinCC Basic (TIA Portal) No
● WinCC Comfort (TIA Portal) No
● WinCC Advanced (TIA Portal) No
● WinCC Professional (TIA Portal) No
Languages
Online languages
● Number of online/runtime languages 5
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Task planner Yes
Help system Yes
● Number of characters per info text 320
● Number of tooltips 0
Message system
● Number of alarm classes 32
● Number of messages 500
● Bit messages Yes
— Number of bit messages 500
● Analog messages Yes
— Number of analog messages 20
● Telegram message procedure Alarm S No
● System messages HMI Yes
● System messages PLC Yes
● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) No
● Lines 1
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● acoustic feedback No
● First/last value Yes
Variables
● Number of variables per device 250
● Number of variables per screen 20
● Limit values Yes
● Multiplexing Yes
● Structures No
Images
● Number of configurable images 250
● Permanent window/default Yes
● Start screen configurable Yes
● Image selection by PLC No
● Image number in the PLC No
Image objects
● Text objects 500 text elements
● Number of I/O fields per image 20
● Number of date/time fields 0
● Index of screen context No
● Return No
● Graphics object Bit maps, icons, icon (full-screen), vector graphics
— Icons 1
— Icon (full screen) 1
Complex image objects
● Status/control Not possible
● dynamic objects Diagrams, bar graphs
— Number of curves per diagram 1
● Bar graphs
— Number of bars per chart 5
● Sliders
— Number of slides per image 0
● Pointer instruments
— Number of analog indicators per image 0
● Limit value lines Yes
● Number of alphanumerical fields 0
— alphanumeric fields per image 0
● Number of numerical fields 0
— numerical fields per image 0
● Number of password fields 0
● Number of visible switches per project 0
— visible switches per image 0
— hidden switches per image 0
● Number of status switches per project 0
— Number of status switches per image 0
● Number of selector switches per project 0
— Selector switches per image 0
● Number of decade switches per project 0
— Decade switches per image 0
● Number of signal lamps per project 0
— Signal lamps per image 0
Attributes for dynamic objects
● Color change No
● X/Y movement No
● Hide Yes
● Angle of rotation No
Lists
● Number of text lists per project 150
● Number of graphics lists per project 100
Security
● Number of user groups 1
● Number of users 1
● Password export/import Yes
Transfer (upload/download)
● Transfer of configuration serial
Process coupling
● Connection to controller for S7-200, see section on “System interfaces”
● S7-200 Yes
— PPI (point-to-point) Yes
— PPI network Yes
— MPI Yes
— PROFIBUS DP No
● S7-300/400 No
— MPI No
— PROFIBUS DP No
— PROFINET No
● S5 No
— serial No
— PROFIBUS DP No
● TI 505 No
● Allen Bradley (DF1) No
● Allen Bradley (DF485) No
● Mitsubishi (FX) No
● Mitsubishi (MP4) No
● Telemecanique (ADJUST) No
● Telemecanique (Uni-Telway) No
● OMRON (LINK/Multilink) No
● Modicon (Modbus) No
● GE-Fanuc (SNP) No
Functions
● Key repeat No
● TAB sequence Yes
● Calculating functions Yes
● Animate No
● Menu tree editor No
● Unit switchover No
Service tools/configuration aids
● Clean screen Yes
● Touch calibration Yes
● Backup/Restore manually Yes
● Simulation No
● Device switchover Yes
● Delta transfer No
● Monitoring function for battery and memory No
● Trace (operation archive) No
Expandability/openness
● Open Platform Program No
Peripherals/Options
Peripherals
● SIMATIC HMI MM memory card: Multi Media Card No
Additional software components loadable Yes
Dimensions
Width of the housing front 212 mm
Height of housing front 156 mm
Mounting cutout, width 198 mm
Mounting cutout, height 142 mm
Overall depth 45 mm
Weights
Weight (without packaging) 0.75 kg