Unitronics M91 2 R6 ZK1 PLC


Brand: Unitronics

Model: M91 2 R6 ZK1

Specifications : 

PLC: 

  • Shaft-encoder inputs and PWM outputs
  • Direct temperature inputs
  • Auto-tune PID, up to 4 loops
  • Date & time-based control Database
  • Full source upload

HMI:

  • Up to 80 user-designed screens
  • Multilingual: supports over 15 languages and 20 graphic symbols
  • Scroll between pre-programmed recipes/menus
  • Memory and communication monitoring  via HMI – No PC needed

Communications:

  • SMS messaging via GSM
  • Remote access utilities
  • PC access via MODBUS or OPC server
  • Supports MODBUS protocol
  • CANbus  (in C models only)
  • User-defined ASCII strings, enable communication with external devices
  • RS232/RS485 built-in port

I/O:

I/O options include digital, analog, high-speed, temperature & weight measurement. See table below:

Condition: Used/Refurbished

Warranty: Three months.

Call for Repair

Unitronics M91 2 R6 ZK1 PLC with textual HMI and keyboard

Unitronics M91 2 R6 ZK1 PLC : 

An affordable All-in-One programmable controllers: a smart PLC with a textual HMI and keyboard, plus onboard I/O configurations; expands up to 150 I/Os.

Specifications:

PLC: 

  • Shaft-encoder inputs and PWM outputs
  • Direct temperature inputs
  • Auto-tune PID, up to 4 loops
  • Date & time-based control Database
  • Full source upload

HMI:

  • Up to 80 user-designed screens
  • Multilingual: supports over 15 languages and 20 graphic symbols
  • Scroll between pre-programmed recipes/menus
  • Memory and communication monitoring  via HMI – No PC needed

Communications:

  • SMS messaging via GSM
  • Remote access utilities
  • PC access via MODBUS or OPC server
  • Supports MODBUS protocol
  • CANbus  (in C models only)
  • User-defined ASCII strings, enable communication with external devices
  • RS232/RS485 built-in port

I/O:

I/O options include digital, analog, high-speed, temperature & weight measurement. See table below:

 

  • All 10 inputs can be set to pnp (source) or npn (sink) via a single jumper and appropriate wiring.
  • All 10 inputs can function in 12 VDC or 24 VDC; set via a single jumper and appropriate wiring.
  • npn (sink) inputs use voltage supplied from the controller’s power supply.
  • Inputs #0, #2 and #4 can each function as either high-speed counter or as part of a shaft encoder. In each case, high-speed input specifications apply. When used as a normal digital input, normal input specifications apply.
  • Inputs #1, #3 and #5 can each function as either counter reset, or as a normal digital input; in either case, specifications are those of a normal

Input impedance >100KQ for voltage 500Q for current Galvanic isolation None
Resolution (except 4-20mA) 10-bit (1024 units)
Resolution at 4-20mA 204 to 1023 (820 units)
Conversion time Synchronized to scan time
Absolute max. rating +15V Full scale error +2LSB Linearity error +2LSB
Status indication Yes, see Note
Note: The analog value can also indicate when the input is functioning out of range. If an analog input deviates above the permissible range, its value will be 1024.
Voltage connection
+V 12 VDC -OV or 24 VDC
[|+— Circuit protection device.

Manual
Show Other Products